Viking VXD Preaction Fire System with Monitored Electric Release
Shipping calculated at checkout
The Viking VXD Preaction Fire System with Monitored Electric Release is engineered to protect water-sensitive commercial environments such as data centers, museums, and libraries from accidental water discharge. Installed within preaction fire suppression assemblies, this single-interlocked system utilizes a dual-activation process that introduces water into the sprinkler piping only after an independent detection system confirms a fire condition, significantly minimizing the risk of costly water damage from pipe breaches or mechanical damage.
This assembly complies with NFPA 13 standards for monitored release solenoids and satisfies life safety code mandates for supervised preaction systems. The network relies on pneumatic supervision using pressurized air or nitrogen to continuously monitor the piping and trigger a low air supervisory alarm if pressure drops, ensuring immediate fault notification.
- Electric Solenoid Activation: Controlled by an approved release control panel and independent detection system for precise operational response.
- Pneumatic Supervision: Maintains pressurized air or nitrogen in the sprinkler piping to continuously monitor system integrity and initiate low-air alarms.
- Durable Material Construction: Built with high-grade brass and galvanized finishes to deliver long-term corrosion resistance and mechanical strength.
- Installation Flexibility: Available in loose trim or factory-assembled pre-trimmed riser packages containing a deluge valve, riser check valve, gauges, and manifolds.
| Specification | Details |
|---|---|
| Manufacturer / Brand | Viking |
| Model / Series Number / SIN | VXD Single-Interlocked Preaction System |
| Connection / Thread Size & Type | N/A |
| Pressure Rating (WWP / Max Working Pressure) | N/A |
| K-Factor | N/A |
| Temperature Rating / Response Type | Electric Release / Pneumatic Supervision |
| Material / Body Construction | High-grade brass and galvanized finishes |
| Agency Listings & Approvals | UL Listed, FM Approved |
| Applicable NFPA Standards | NFPA 13 |
Contractors and facility managers must verify all local Authority Having Jurisdiction (AHJ) requirements and review engineering design parameters before commencing installation.
Documentation: Download Manufacturer Technical Data & Cut Sheet (PDF)
If you qualify for sales tax exemption, please submit your exemption details and supporting documents. Our team will review your request, and once approved, your account will be updated to receive tax-exempt checkout on eligible purchases.
If you can't find the product you're looking for, send a quote request below.
Return policy
You have 30 days to return the product. Returned items must be in the original packaging, contain all components, and be in new condition. Returns may require additional information or a photo of the item(s) to process the return. Returns received without the proper return label may take more than 10 business days to credit.
Original shipping fees are non-refundable.
You must provide a receipt or proof of purchase.
A 25% restocking fee will be applied to all returned items.
Customer is responsible for return shipping costs.
Special orders are non-cancelable and non-refundable.
Shop.water-services.us reserves the right to refuse or limit any returns that, in Shop.water-services.us’s sole judgment, appear to be fraudulent, abusive, in violation of these terms, or otherwise inappropriate.
For additional Return Policy Information, click here